41638 Eastman Dr. Suite B
Murrieta, CA 92562
(888) 659-2665

Local Reviews
for valley center, ca

Rated 4.9 out of 5 stars based on 18 customer reviews

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Quick, accurate repair.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Excellent service technicians. Quick in trouble shooting.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Simi annual tune up

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Simi Annual cleaning

Great service all around. Keep system top notch.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Your technician was solid, professional and very helpful!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Semi annual inspection

  • Overall Experience
  • Quality
  • Price
  • Convenience

Yearly Maintenance Service Inspection

Excellent, Quality service provided. Jorge was very professional and highly skilled!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Servce

Micheal explained everything well and diagnosed the issues with the cooling and heating. He was on time did what was needed and cleaned up everything afterwards.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service wonderful and caring technitions

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

The best service in town.

  • Overall Experience
  • Quality
  • Price
  • Convenience

⭐️ ⭐️ ⭐️ ⭐️ ⭐️

The service tech was knowledgeable, he kept me updated on everything he was doing, he was very thorough in the work he had to do to get our extremely dirty furnace and air conditioner clean. He was also friendly, polite and followed COVID rules.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome

He was prompt clean and knowledgeable. He review the system and gave all options on how to proceed.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Courteous and knowledgeable

Very pleased with service and professionalism.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome!

My unit works better than it ever has!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for valley center, ca

Nick D.

Nick D. Job Checkin

Diagnostic on carrier furnace


Nick D.

Nick D. Job Checkin

Warranty call on Lennox equipment


Dylan E.

Dylan E. Job Checkin

Heating Maintenance


Nick D.

Nick D. Job Checkin

Warranty on Lennox heat pump

Warranty on Lennox heat pump

Jared F.

Jared F. Job Checkin

Performed a furnace tune up on a Kenmore system. Checked temperatures, blower motor condition, and thermostat functionality.

Performed a furnace tune up on a Kenmore system. Checked temperatures, blower motor condition, and thermostat functionality.

Sergio R.

Sergio R. Job Checkin

Performed heating maintenance on package unit

Performed heating maintenance on package unit

Isaac O.

Isaac O. Job Checkin

Ac maintenance


Sergio R.

Sergio R. Job Checkin

Furnace Maintenance comfort pro system

Furnace Maintenance comfort pro system

Christian J.

Christian J. Job Checkin

HVAC maintenance valley center


Jimmy G.

Jimmy G. Job Checkin

arrived on site to diagnose a no heating unit. Client stated they heater is not blowing any hot air out and it’s just cold air. Cycled unit on and sequence of operation did not complete itself. Started testing parts. Found the pressure switch was not closing. Inducer motor would keep running until a lock out. Tested pressure switch and manually got it to close as I pulled air from switch. But inducer could not close switch. Traced back to ventilation. Checked b-vent for n furnace and roof. Found nothing was clogged up. Tested inducer pressure. Found it was not pulling enough to close switch. Removed b-vent to see if ventilation was issues and cycled and unit still didn’t close switch. Verified with manometer inducer was pulling 0.6 and pressure switch was rated for 0.65. Advised and verified with supervisor and he did stated inducer may just not pulling enough to close it. After running bad for so long pressure switch may have gotten weak and now just fail from it not turning on f


Jimmy G.

Jimmy G. Job Checkin

Arrived on site to see diagnose a no heating unit. Had another’s tech come out and checked everything and wanted to inspect b-vent on roof. He was unable to get get one the roof. Came out and inspect unit and found b-vent covered with soot. Found it not clogged up but dirty. Inspect heater and gas line. Asked client if she knew if she was on natural gas or propane and she stated she is on propane as this whole park is supplied propane. Found that unit did not have a propane kit installed. Due to that the unit may have ran for a short time but unit was not going to stay running properly due to fuel not burning properly. Advised office of findings and they are aware LP kit is missing. Advised client office will be ordering kit and will be getting warranty to come back out to replace igniter and install propane kit to unit. She is aware and okay with so. Office will call her once parts arrive to get her back on the schedule. She is aware and okay with so. Due to finding advise to not be


Jorge C.

Jorge C. Job Checkin

Arrived on site to perform diagnostic. Homeowner states that system is not heating. Cycled system for heating. Unit initiated heating cycle, but never ignited. Pulled out heating section and found that igniter was completely burnt up and the wires were also burnt. Everything was completely charred up. Replaced ignitor. Cycled system for heating. Unit kicked on and started heating. Flame is not burning correctly, and is rolling over and burning new ignitor. Verified that gas pressure is set correctly, set at 3.3inwc. Roof hood is completely charred up, indicating improper combustion. Flue needs to be checked at roof. Sending a smaller tech out due to weaker mobile home roof. System is not operational upon departure.


Jorge C.

Jorge C. Job Checkin

Arrived on site to perform diagnostic on unit. Upon arrival, homeowner states that system didn’t work but now has started working fine and has been heating but would still like it looked at. Cycled system for heating. Verified proper heating sequence of operations. Temperature rise is within range. Cleaned flame sensor as it was dirty. Filter is pretty dirty. Recommended replacement. Went ahead and replaced filter with approval. Ensure all supplies were open. Thermostat is operating normally. System is fully operational upon departure. No issues at this time.


Brent L.

Brent L. Job Checkin

Technician arrived to perform heating tune up for package unit -Flame sensor was cleaned off -Filter was replaced -Heating elements are working efficiently -Electrical connections tightened -Coil is clean -Heat exchanger in good condition


Kendall O.

Kendall O. Job Checkin

Performed combo tuneup on 2 year old Lennox furnace and 18 year old Carrier condenser. Indoor Unit: Cleaned return grate. Installed new merv 16 filter. Tested static pressure. Inspected blower compartment. Blower wheel is clean and balanced. Inspected electrical connections. Tested resistance of hot surface igniter. Inspected flame sensor. Found air scrubber catalyst to be out, Randy was notified of this. Temperature rise was within limits and temperature split is normal. Outdoor Unit: Performed deep cleaning of condenser coil fins and exterior unit. Inspected electrical components. Start contactor is clean, secondary motor control is within limits, however compressor start amps are high at 131 amps. A compressor saver kit was recommended. Refrigerant temperatures and pressures were normal. Upon departure system is operational.